فئات

Three-Phase Oil-Immersed Transformer – Reliable Power Solution by Jiangsu Xinhong Electrical

Jul 17th,2026 17 الآراء

1. Product Overview

Jiangsu Xinhong Electrical Equipment Co., Ltd. , a professional oil immersed transformer manufacturers based in China, has been dedicated to the research, development, and production of high-quality oil immersed transformer products for years. Our three-phase oil-immersed transformers are engineered to meet the stringent demands of global power systems, offering outstanding performance, long service life, and cost-effective operation.

As a leading name among oil immersed transformer China manufacturers, Xinhong Electrical combines advanced manufacturing technology, rigorous quality control, and deep industry expertise to deliver transformers that power progress across the globe.

2. What Is a Three-Phase Oil-Immersed Transformer?

A three-phase oil-immersed transformer is a static electrical device that transfers electrical energy between circuits through electromagnetic induction, using transformer oil as both an insulating medium and a cooling agent. The core and windings are immersed in a tank filled with high-quality insulating oil, which efficiently dissipates heat generated during operation and provides excellent electrical insulation.

These transformers are typically used in outdoor substations, utility distribution networks, and industrial power systems where reliable, high-capacity voltage transformation is required.

Key Components

  • Core: Made of high-permeability cold-rolled grain-oriented silicon steel, minimizing hysteresis and eddy current losses.

  • Windings: Available in copper or aluminium conductors, wound with precision to ensure uniform flux distribution.

  • Insulating Oil: High-grade mineral oil or natural ester oil, providing superior dielectric strength and thermal conductivity.

  • Tank: Robust, fully sealed construction to prevent oil leakage and moisture ingress.

  • Conservator & Breather: Maintain oil volume and prevent contamination.

  • Bushings: High-voltage and low-voltage porcelain or composite bushings for safe external connections.

3. Product Range & Specifications

Xinhong Electrical offers a comprehensive range of three-phase oil-immersed transformers to suit diverse applications and capacity requirements.

Parameter Range
Rated Capacity 50 kVA – 10,000 kVA
Voltage Class Up to 35 kV
Frequency 50 Hz / 60 Hz
Cooling Method ONAN (Oil Natural Air Natural) 
Winding Material Copper / Aluminium (optional)
Standard Compliance IEC 60076, ANSI C57.12, GB/T 6451

Standard Models Available

  • S11 Series – Energy-efficient distribution transformers

  • S13 Series – Ultra-low loss, high-efficiency design

  • S20 Series – Next-generation amorphous alloy core transformers

  • Custom Designs – Tailored to specific voltage, capacity, and environmental requirements

3. Key Advantages of Xinhong Three-Phase Oil-Immersed Transformers

1. High Efficiency & Low Losses

Xinhong transformers are designed with optimized magnetic circuits and high-quality silicon steel cores, achieving significantly reduced no-load and load losses. Our S13 and S20 series transformers exceed the most stringent energy efficiency standards, helping customers lower operational costs and reduce carbon footprints.

2. Superior Cooling Performance

The transformer oil circulates naturally or with forced air assistance, ensuring even heat distribution and preventing hot spots. This allows our transformers to operate reliably even under sustained overload conditions.

3. Robust & Durable Construction

Built with heavy-duty tank materials, precision-welded seams, and advanced sealing technology, Xinhong three-phase oil-immersed transformers are resistant to harsh environmental conditions, including high humidity, temperature extremes, and corrosive atmospheres.

4. Long Service Life

With high-grade insulating oil, premium winding materials, and meticulous manufacturing processes, our transformers deliver a design life of over 25 years, minimizing the total cost of ownership.

5. Customizable Options

We offer flexible customization – from capacity and voltage ratings to winding materials, tapping ranges, and accessory configurations – ensuring that each transformer perfectly matches the specific needs of your project.

6. Compliance with International Standards

All Xinhong transformers are designed, tested, and certified in accordance with IEC 60076, ANSI C57.12, and other relevant international standards, ensuring global compatibility and customer confidence.

4. Applications

Our three-phase oil-immersed transformers are trusted by customers across a wide spectrum of industries and sectors:

  • Utility Power Grids – Distribution and transmission substations

  • Industrial Facilities – Factories, mines, and manufacturing plants

  • Commercial Buildings – Shopping malls, office towers, and hotels

  • Residential Communities – Apartment complexes and housing developments

  • Renewable Energy – Solar farms, wind power plants, and hydro stations

  • Infrastructure Projects – Airports, railways, and port facilities

5. Oil-Immersed Transformer vs. Dry-Type Transformer

When selecting a transformer for a project, one of the most common decisions is whether to choose an oil immersed transformer vs cast resin transformer (also known as a Dry transformer). Each type has its own strengths, and the choice depends on the specific application environment.

Oil-Immersed Transformer – Advantages

  • Excellent heat dissipation, suitable for high-capacity and overload conditions

  • More compact footprint for the same power rating

  • Longer operational life (typically 25–30 years)

  • Lower initial cost for large-capacity units

  • Ideal for outdoor installations

Cast Resin Transformer (Dry Transformer) – Advantages

  • No oil – eliminates fire and environmental risks

  • Minimal maintenance – no oil testing or filtration

  • Suitable for indoor installations with strict fire safety requirements

  • Environmentally friendly – no risk of oil leakage

Xinhong’s Recommendation

For outdoor, high-capacity, and high-reliability applications, the oil-immersed transformer remains the preferred choice. For indoor environments with limited ventilation or stringent fire codes, a cast resin transformer may be more appropriate. Xinhong Electrical manufactures both types, and our technical team is ready to assist you in making the optimal selection.

6. Prefabricated Substation Integration

In addition to standalone transformers, Xinhong Electrical offers complete prefabricated substationsolutions. Our compact substations integrate the three-phase oil-immersed transformer with high-voltage and low-voltage switchgear, metering, and protection devices in a single, weatherproof enclosure.

As one of the professional prefabricated substation manufacturers in China, we provide turnkey solutions that significantly reduce installation time, civil works, and on-site commissioning efforts – ideal for urban distribution networks, industrial parks, and temporary power supply projects.

Key benefits of our prefabricated substations include:

  • Space-saving, modular design

  • Factory pre-assembled and tested – ready for immediate operation

  • Customizable to meet specific grid requirements

  • Suitable for both indoor and outdoor installations

7. Quality Assurance & Manufacturing Excellence

At Jiangsu Xinhong Electrical Equipment Co., Ltd., quality is not just a standard – it is the foundation of our business. Our manufacturing facility is equipped with advanced production lines, including:

  • Automatic foil winding machines for precise winding

  • Vacuum drying and oil impregnation systems

  • High-voltage testing laboratories

  • Comprehensive quality inspection stations at every production stage

Every transformer undergoes a series of rigorous tests before leaving our factory, including:

  • Ratio and polarity tests

  • Winding resistance measurements

  • No-load loss and load loss tests

  • Impulse voltage withstand tests

  • Partial discharge measurements

  • Oil dielectric strength tests

Our commitment to quality has earned us certifications including ISO 9001, ISO 14001, and OHSAS 18001, reflecting our dedication to quality management, environmental responsibility, and occupational health and safety.

8. Why Choose Xinhong Electrical?

  • Extensive Experience – Years of specialization in transformer design and manufacturing

  • Global Reach – Products exported to Southeast Asia, the Middle East, Africa, South America, and beyond

  • Technical Expertise – A team of experienced engineers providing professional support from design to after-sales

  • Competitive Pricing – Optimized production processes delivering premium quality at affordable costs

  • Customer-Centric Approach – Flexible solutions tailored to individual project requirements

9. Conclusion

The three-phase oil-immersed transformer remains a cornerstone of modern power systems, offering unmatched reliability, efficiency, and longevity. As a trusted oil immersed transformer manufacturers in China, Jiangsu Xinhong Electrical Equipment Co., Ltd. is committed to delivering transformers that not only meet but exceed customer expectations.

Whether you require a standard distribution transformer, a custom-engineered unit, or a complete prefabricated substation solution, Xinhong Electrical is your reliable partner. We invite you to explore our product range and experience the Xinhong difference – where quality, innovation, and customer satisfaction come together.