• 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA three phase oil immersed distribution transformer 33kV 22kV 11kV to 0.4kV pure copper winding Xinhong Electrical
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA three phase oil immersed distribution transformer 33kV 22kV 11kV to 0.4kV pure copper winding Xinhong Electrical
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV

1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV

  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA three phase oil immersed distribution transformer 33kV 22kV 11kV to 0.4kV pure copper winding Xinhong Electrical
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV
  • 1250kVA Three Phase Oil Immersed Distribution Transformer | 33kV 22kV 11kV to 0.4kV

Description

Product Overview

This 1250kVA oil immersed power transformer is a three-phase step-down distribution transformer, supporting multiple high voltage input options: 33kV, 22kV, 11kV, with low voltage output 0.4kV. Our oil immersed transformer adopts high-quality pure copper winding, designed strictly according to IEC60076 international standard. It is widely used for power grid distribution, power substations, industrial plants, mining projects and rural electrification projects. As a professional oil immersed transformer china manufacturer.
Xinhong Electrical supplies stable, low loss, energy-saving oil immersed distribution transformers with full test reports and complete certifications.

Main Technical Parameters

Item Specification
Rated Capacity 1250kVA
Phase 3 Phase
High Voltage 33kV / 22kV / 11kV (customizable)
Low Voltage 0.4kV(customizable)
Cooling Method ONAN / ONAF
Winding Material Pure Copper/Aluminum
Connection Group Dyn11 / Dyn5 (optional)
Standard IEC60076
Frequency 50Hz / 60Hz customizable


Key Features

✅ Low no-load loss & low load loss, excellent energy saving performance
✅ Pure copper coil winding, better conductivity, lower temperature rise, longer service life
✅ High-strength corrugated tank, good heat dissipation, reliable sealing, anti-oil leakage
✅ Stable operation, strong overload capacity, suitable for long-time continuous running
✅ Multiple HV voltage options: 11kV,22kV,33kV to match different regional grid standards
✅ Complete protection design: oil level gauge, temperature indicator, pressure relief valve, conservator optional
✅ CE, ISO9001, CB certified, fully compliant for export worldwide


Application Scenarios

This 1250kVA 33kV 22kV 11kV to 0.4kV oil immersed distribution transformer is ideal for:

  • Urban & rural power distribution substations
  • Factory power supply, industrial park
  • Mining, quarry, water pumping station projects
  • Solar / wind power station booster & distribution system
  • Overseas EPC power construction projects


Product Standard & Certification

All our oil immersed power transformers are manufactured under IEC60076 standard. Certificates: ISO9001, CE, CB. We can provide test report, factory inspection certificate, CO and other documents for customs clearance.


Packing & Delivery

Export standard wooden case / steel frame packing. Anti-rust treatment before shipment. We support sea freight, land freight for bulk orders. Our factory has sufficient production capacity for large quantity orders of 1250kVA oil immersed transformers.


Why Choose Xinhong Electrical

We are a professional transformer manufacturer located in Jiangsu, China, with 15 years production experience and 27000㎡ workshop. We supply oil immersed transformer and cast resin dry type transformer from 100kVA to 25MVA, support non-standard custom design according to client’s grid requirement. Fast quotation, strict factory testing, reliable after-sales service for global power contractors and distributors.

FAQ 

Q: Can this 1250kVA oil transformer support 60Hz?
A: Yes, 50Hz and 60Hz are both customizable for different countries.

Q: What connection vector group can you offer?
A: Dyn11 is standard, Dyn5 is optional.
Q: Is copper winding standard for this model?
A: Yes, we adopt pure copper winding as default, aluminum winding is optional on request.